Humidity and Temperature
Probes and Sensors

Standard Humidity probe - Rotronic HC2A-S,SH
- Operating range -50...100 °C / 0...100 %RH
- Accuracy, ±0.8 %RH, ±0.1 K, at 23 °C ±5 K
- Production, Processing, Storage | HVAC- Monitoring Buildings, Offices, Museums | Pharma & Food & Cosmetic Industry

Meteo Humidity Probe - Rotronic HC2A-S3, S3H
- Range of application -50…100 °C / 0…100 %RH
- Accuracy: ±0.8 %RH, ±0.1 K, at 23 °C ±5 K
- Meteorology & Wheater Forecast | Outdoor Environments | Reference Probe for Snow Guns, Meteo & Research Stations

Industrial Humidity Probe - Rotronic HC2A-IC
- Measuring range -100...200 °C / 0...100 %RH
- Accuracy: ±0.8 %RH, ±0.1 K, at 23 °C ±5 K
- Industrial Production - High temperature | Industrial Drying fluid bed & coating | Climate & Test and Bio chambers

Probe for Hydrogen Peroxide Environments H2O2 – Rotronic HC2A-S(M)-HH
- Operating range 0...60 °C / 0...100 %RH
- Accuracy, ±1.0 %RH, ±0.1 K, at 10...30°C before and after diffusion phase
- Decontamination in Pharma, Hospital, Healthcare and Life-science | Sterilization of operating tools, rooms & transfer hatches | Germfree Production & Packaging

Industrial Humidity Probe for high pressure – Rotronic HC2A-IM
- Measuring range, -100...200 °C / 0...100 %RH
- Accuracy, ±0.8 %RH, ±0.1 K, at 23 °C ±5 K
- Industrial Pharma & Food production - High temperature | Industrial Drying Applications & Coating in corrosive environment | Climate & Test and Bio chambers

Industrial Humidity Probes - Rotronic HC2A-IE
- Measuring range -100...200 °C / 0...100 %RH
- Accuracy: ±0.8 %RH, ±0.1 K, at 23 °C ±5 K
- Pressured Systems – Leakage tight | Beverage & Process Pressure | Climate & Test and Bio chambers

Handheld Probe - Rotronic HC2-HP28
- Range of application: -40...85 °C / 0...100 %RH
- Digital interface (UART) and scalable analog outputs, 0...1 V
- Quality testing for building material and laboratories | Quick Inspection & Spot checking | Measurement in bulk materials, bricks and concrete

Steel Humidity Probe – Rotronic HC2A-SM
- Application range -50...100 °C / 0...100 %RH
- Accuracy: ±0.8 %RH, ±0.1 K, at 23 °C ±5 K
- Pharma & Food Production and Processing | Hygienic & Safe - reliable and accurate | Industrial Manufacturing - corrosive resistant

Humidity and Temperature Probes - Rotronic PC33 & PC52, PC62 & PC62V, PCMini52
- Measuring range: -20…80 °C / 0…100 %rh
- Accuracy: ±2 or ±3% rh, ±0.2 or ±0.3K
- HVAC and controlled environment

Digital Humidity and Temperature Probe - Rotronic HCD-S-MOD Modbus
- Measures relative humidity and temperature
- Excellent accuracy, reproducibility and long-term stability
- Digital Monitoring Production, Processing, Storage | HVAC - Automated Building, Office and Museum monitoring | Digital Monitoring Pharma & Food & Cosmetic Industry

Special Humidity Probes - Rotronic HC2-HK/C Series
- Measuring range, -40...85 °C / 0...100 %RH
- Accuracy, ±0.8 %RH, ±0.1 K, at 23 °C ±5 K
- Industrial Process Pharma & Food production - High temperature | Industrial Drying fluid bed & coating – Spot check | Climate & Test and Bio chambers

ATEX Humidity Probes - Rotronic HC2-SM-/ IM-/ IE-Ex
- Measuring Range: -40…85 °C 0…100 %RH
- Accuracy: ±0.8 % RH / ± 0.1 K
- Safe operation in areas with explosion risk | Intrinsically safe probes | Interchangeable probes for fast exchanges

OEM Probe Temperature and Humidity - Rotronic XD
- Accuracy ± 0.8 %rh / ±0.2 K at 23 °C
- Range of applications electronics. -40…85 °C / 0…100 %rh
- Supply voltage range from 5…24 VDC and freely scalable outputs

OEM Module Temperature and Humidity - Rotronic HC2-ROPCB/01
- Accuracy ± 0.8 %rh / ±0.1 K at 23 °C
- Range of applications electronics. -50…100 °C / 0…100 %rh
- Adjusted at 23 °C and 10, 35, 80 %rh

Industrial Humidity Probes - Rotronic HC2-P05
- Range of application: -40…85 °C / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
- Quality testing for building material and laboratories | Quick Inspection & Spot checking | Measurement in bulk materials, bricks and concrete

Adaptor for Rotronic PT100 Temperature Probes - Rotronic HC2A-PT100
- Extended temperature measurement range from -100 up to 400 °C
- Advanced probe housing and construction
- Hot swappable (Mounted probe)

Handheld Probe for Measuring Humidity in Paper Stack | Rotronic HC2-HS28 | PST
- Measuring range, -40...85 °C / 0...100 %RH
- Accuracy, ±0.8 %RH, ±0.1 K, at 23 °C ±5 K
- Industrial Process Pharma & Food production - High temperature | Industrial Drying fluid bed & coating – Spot check | Climate & Test and Bio chambers